156 VAV-PRC011M-EN
Application Considerations
Additional VAV System and Product References
VAV Systems Air Conditioning Clinic
This clinic is designed to explain the system components, the system configurations, many of the
VAV system options and applications. A great resource for VAV system understanding.
Literature Order Number: TRG-TRC014-EN
Intelligent Variable Air —
An EarthWise System from Trane for chilled-water applications
This catalog describes Trane's EarthWise approach to chilled-water VAV systems, which includes
pre-packaged, optimized system controls to consistently deliver energy savings, interactive
operator dashboards that demonstrate real time savings, and intelligent analytics that identify
efficiency improvement opportunities, helping sustain a high level of performance for life.
Literature Order Number: APP-PRC002-EN
Intelligent Variable Air —
An EarthWise System from Trane for packaged DX applications
This catalog describes Trane's EarthWise approach to packaged DX rooftop VAV systems, which
includes pre-packaged, optimized system controls to consistently deliver energy savings,
interactive operator dashboards that demonstrate real time savings, and intelligent analytics that
identify efficiency improvement opportunities, helping sustain a high level of performance for life.
Literature Order Number: APP-PRC003-EN
Rooftop VAV Systems Applications Engineering Manual
Discusses proper design and application of packaged rooftop, VAV systems. Topics include: basic
system operation, benefits and drawbacks of a rooftop VAV system, in-depth coverage of system
components (packaged rooftop unit, VAV terminal units, air distribution system, hot water heating
system), solutions to address common design challenges (thermal zoning, ventilation, humidity
control, energy efficiency, acoustics), several system variations (cold air distribution, single-zone
VAV, air-to-air energy recovery), and common unit-level and system-level control functions
(including system optimization strategies).
Literature order Number: SYS-APM007-EN
Table 53. Conversions of velocity, pressure, and flow rate
To convert From To Multiply by
Velocity
Velocity
Ft/min
M/s
M/s
Ft/min
0.00508
196.850
Pressure
Pressure
Pressure
Pressure
Pressure
Pressure
Psi
Ft of water
In. of water
Pa
Pa
Pa
Pa
Pa
Pa
Psi
Ft of water
In. of water
6894.76
2988.98
249.082
0.000145038
0.000334562
0.00401474
Flow Rate
Flow Rate
Flow Rate
Flow Rate
Flow Rate
Flow Rate
Cfm
Cfm
Gpm
m
3
/s
L/s
L/s
L/s
m
3
/s
L/s
Cfm
Cfm
Gpm
0.4719
0.000471947
0.0630902
2118.88
2.1191
15.8503
Vista de pagina 155
1 2 ... 151 152 153 154 155 156 157 158

Comentarios a estos manuales

Sin comentarios

Antec Plus1000 Series manuels

Manuels d'utilisation et guides de l'utilisateur pour Non Antec Plus1000 Series.
Nous fournissons des manuels en pdf 1 Antec Plus1000 Series à télécharger gratuitement par type de document : Manuel de l'utilisateur


Antec Plus1000 Series Manuel de l'utilisateur (4 pages)


marque: Antec | Catégorie: No info | Taille: 0.13 MB |

 

Table des matières





Plus de produits et de manuels pour Non Antec

Modèles Type de document
P182 Manuel de l'utilisateur   Antec P182 User`s manual, 9 pages
Sonata II 500 Manuel de l'utilisateur   Sonata III 500_102307.indd, 8 pages
P182 Manuel de l'utilisateur   Antec P182 Midi Tower, 3 pages