PKG-SVX14A-EN
Installation, Operation, and
Maintenance
Midrange Self-Contained Units
October 2008
Models SCWH/SCRH
3, 5, 7.5, 10, 12, & 15-tons
“AO” and later design sequence
Vista de pagina 0
1 2 3 4 5 6 ... 35 36

Indice de contenidos

Pagina 1 - Maintenance

PKG-SVX14A-ENInstallation, Operation, andMaintenanceMidrange Self-Contained UnitsOctober 2008Models SCWH/SCRH3, 5, 7.5, 10, 12, & 15-tons“AO” and

Pagina 2 - 2 PKG-SVX14A-EN

10 PKG-SVX14A-ENProper Lifting ProcedureFollow these instructions and referenceFigure I-PC-3.1. Slide a fork lift into the openingprovided on the unit

Pagina 3 - PKG-SVX14A-EN 3

PKG-SVX14A-EN 11dimensions &weightsInstallation3 & 5-tonsSCWH/SCRHSCRHSCWHvertical dischargehorizontal discharge(field converted)SCWH/SCRH dim

Pagina 4

12 PKG-SVX14A-ENdimensions &weights7.5-tonsSCWH/SCRHInstallationSCWHvertical dischargehorizontal discharge(field converted)SCWH/SCRH weight, lbs.u

Pagina 5

PKG-SVX14A-EN 13dimensions &weightsInstallation10, 12, & 15-tons with top-mounted fan configurationSCWH/SCRHhorizontal discharge(field convert

Pagina 6

14 PKG-SVX14A-EN10, 12, & 15-tons with side-mounted fan configuration, field convertedSCWH/SCRHSCWH/SCRH Dimensions, in.unittons A C D E F G10 65.

Pagina 7

PKG-SVX14A-EN 15dimensions &weightsInstallationPlenumPlenum dimensions & weight, in-lbs.unit size A B weight3-ton 31.89 22.24 445-ton 36.41 24

Pagina 8

16 PKG-SVX14A-ENdimensions &weightsInstallationABDC0.430.280.390.391.031.031.081.573.190.750.755.901.00 NPT1.381.3817.5020.261.388.272.180.599.549

Pagina 9

PKG-SVX14A-EN 17mechanicalrequirementsDuct ConnectionsInstall all air ducts according to theNational Fire Protection Associationstandards for the “Ins

Pagina 10 - Installation

18 PKG-SVX14A-ENmechanicalrequirementsInstallationRefrigerant Piping (Air-CooledUnits Only)Reference industry recommendationsfor air-cooled unit refri

Pagina 11 - SCWH/SCRH

PKG-SVX14A-EN 19electricalrequirementsInstallationSupply Power WiringIt is the installer’s responsibility to providepower supply wiring to the unit te

Pagina 12

2 PKG-SVX14A-ENgeneralinformationAbout This ManualLiterature Change HistoryUse this manual for commercial self-contained models SCWH and SCRH.This is

Pagina 13

20 PKG-SVX14A-ENelectricalrequirementsInstallationRLA LRA qty. hp FLA qty. hp FLA qtySC*H0303... 208-230V/60Hz/3Ph 12.9 77.00.52.21118.3 30 3.15 19.3

Pagina 14

PKG-SVX14A-EN 21Installation ChecklistReference the checklist below to verify allsteps required to successfully install adeluxe self-contained unit ar

Pagina 15 - 3 & 5-ton units

22 PKG-SVX14A-ENpre-startuprequirementsInstallationPre-Startup ChecklistComplete this checklist after installing theunit to verify all recommendedinst

Pagina 16 - 7.5-ton units

PKG-SVX14A-EN 23Unit Startup Procedures1. Check all electrical connections fortightness.2. Be sure all unit accessories areproperly set and installed.

Pagina 17

24 PKG-SVX14A-ENOperationsequence ofoperationSequence of OperationThe thermostat controls the unitoperation. It has both manual andautomatic switches

Pagina 18 - Electrical Requirements

PKG-SVX14A-EN 25MaintenancegeneralinformationTable M-GI-1. Midrange maintenance general dataSCWH030 SCWH050 SCWH075 SCWH100 SCWH120 SCWH150dimensions,

Pagina 19 - Electrical Data Calculations

26 PKG-SVX14A-ENMaintenancemaintenanceproceduresMaintenance ProceduresThis section describes specificmaintenance procedures that must bepreformed as a

Pagina 20

PKG-SVX14A-EN 27• To assist in reducing power generationemissions, always attempt to improveequipment performance with improvedmaintenance and operati

Pagina 21 - Hazardous voltage!

28 PKG-SVX14A-ENcontrol disarming rearminghigh pressure control (air-cooled & 12-ton water cooled) 624±17.5 psig 464±29 psighigh pressure control

Pagina 22 - Hazardous Voltage!

PKG-SVX14A-EN 29Periodic ChecklistsMonthly ChecklistThe following checklist provides therecommended maintenance schedule tokeep the unit running effic

Pagina 23 - Hazardous voltage!

PKG-SVX14A-EN 3contentsCross reference to related publications/information:Midrange Self-Contained catalog, PKG-PRC012-ENInstallation……………………………………………

Pagina 24 - Operation

30 PKG-SVX14A-ENMaintenancetroubleshootingTroubleshootingUse the following steps and procedures to help correct these common problems.ProblemThe entir

Pagina 25

PKG-SVX14A-EN 31MaintenancetroubleshootingProblemInsufficient coolingPossible cause1. Insufficient air flow due to: a) dirtyevaporator; b) ice on evap

Pagina 26 - Hazardous Voltage!

32 PKG-SVX14A-ENtypical wiringdiagramMaintenance

Pagina 27

PKG-SVX01A-EN 33typical wiringdiagramMaintenance

Pagina 28

34 PKG-SVX14A-ENtypical wiringdiagramMaintenance

Pagina 29

PKG-SVX01A-EN 35typical wiringdiagramMaintenance

Pagina 30

www.trane.comFor more information, contact your local Trane office or e-mail us at [email protected] Order NumberDateSupersedesTrane has a p

Pagina 31

4 PKG-SVX14A-ENInstallationgeneralinformationMidrange Model Number DescriptionFollowing is a complete description of the midrange model number. Each d

Pagina 32 - 32 PKG-SVX14A-EN

PKG-SVX14A-EN 5InstallationgeneralinformationGeneralThe midrange models SCWH/SCRHis a high efficiency, vertical aircondioner. units have either front

Pagina 33 - PKG-SVX01A-EN 33

6 PKG-SVX14A-ENPre-Installation ConsiderationsPre-Installation ChecklistComplete the following checklist beforebeginning unit installation. Verify th

Pagina 34 - 34 PKG-SVX14A-EN

PKG-SVX14A-EN 7Installationpre-installationconsiderations24" FAN ACCESSFRONT RETURNCOIL / ELECTRIC HEATER ACCESSMOTOR / DRIVE ACCESS(RIGHT SIDE)C

Pagina 35 - PKG-SVX01A-EN 35

8 PKG-SVX14A-ENInstallationpre-installationconsiderationsService Access10, 12, & 15-ton SCWH/SRCHwith side-mounted fan configura-tion, field conve

Pagina 36

PKG-SVX14A-EN 9Installationpre-installationconsiderationsTable I-PC-1. Isolator load points, units with a vertical discharge configuration, lbs.model