November 2009
MUA-PRC007-EN
Direct-Fired Make-Up
Air Units
DFIA
DFOA
Product Catalog
Vista de pagina 0
1 2 3 4 5 6 ... 72 73

Indice de contenidos

Pagina 1 - Air Units

November 2009MUA-PRC007-ENDirect-Fired Make-Up Air UnitsDFIADFOAProduct Catalog

Pagina 2 - Introduction

10 MUA-PRC007-ENUnit ConfigurationHorizontal ConfigurationsFor all arrangements shown, controls, gas piping and fan motor are on the near side. Selec

Pagina 3 - Trademarks

MUA-PRC007-EN 11Unit ConfigurationVertical Configurations (DFIA only)For all arrangements shown, the gas piping is on the near side. The electric cont

Pagina 4 - Table of Contents

12 MUA-PRC007-ENDFIAModel Number DescriptionsDigit 1, 2, 3 — Unit DescriptionDFI = Direct fired indoor unitDigit 4 — Development SequenceA = First

Pagina 5 - MUA-PRC007-EN 5

MUA-PRC007-EN 13DFIADigit 34, 35 —Clogged Filter IndicatorAN = Clogged Filter IndicatorDigit 36, 37— Exhaust InterlockAP = Exhaust InterlockDigit 38,

Pagina 6 - Application Considerations

14 MUA-PRC007-ENDFIAFeatures and BenefitsFeature: Basic unit is factory assembled and wired.Benefit: Reduces field installation cost.Feature: Fact

Pagina 7 - What Fuel to Use?

MUA-PRC007-EN 15DFIAReliable Operation The standard unit includes all of the controls needed for trouble-free operation. If the designer does not util

Pagina 8 - Selection Procedure

16 MUA-PRC007-ENDFIAPerformance DataTable 1. Direct-Fired Indoor Air (DFIA) unit—General dataUnit Size 109 112 115 118 120 122 125 130 215 218 220 22

Pagina 9 - Burner Selection Procedure

MUA-PRC007-EN 17DFIA122 1–2211000 2157 5 5 7 -1/2 7-1/2 7-1/2 7-1/2 10 —12000 2353 7-1/2 7-1/2 7-1/2 7-1/2 7-1/2 10 10 1513000 2549 7-1/2 7-1/2 7-1/2

Pagina 10 - Unit Configuration

18 MUA-PRC007-ENDFIA222 2-2225000 2451 15 15 15 15 20 20 20 2526000 2549 15 15 15 20 20 20 20 2527000 2647 15 15 15 20 20 20 25 2528000 2745 15 20 20

Pagina 11

MUA-PRC007-EN 19DFIA1154500 399 447 493 537 580 621 6615000 444 497 548 597 644 690 7345500 488 546 603 657 709 759 8076000 532 596 658 717 773 828 88

Pagina 12 - Descriptions

© 2009 Trane All rights reserved MUA-PRC007-ENIntroductionWhy use Trane Makeup Air Units…Trane’s innovative Direct Fired gas heating systems add warm

Pagina 13

20 MUA-PRC007-ENDFIA22018000 1597 1788 1973 2105 2320 2484 264219000 1686 1888 2082 2269 2449 2622 278920000 1774 1987 2192 2388 2578 2760 293621000

Pagina 14 - Gas burner section

MUA-PRC007-EN 21DFIADimensionsFigure 6. Horizontal arrangement single blowerUnit Components1. Inlet d amper2. R/A section (before Burner)3. V-bank4. B

Pagina 15 - Equipment Approval Options

22 MUA-PRC007-ENDFIAFigure 7. Horizontal arrangement twin blowersUnit Components1. Inlet damper2. R/A section (before Burner)3. V-bank4. Burner secti

Pagina 16 - Performance Data

MUA-PRC007-EN 23DFIAFigure 8. Single blower vertical unitsUnit Components1. Inlet damper2. R/A section (before burner)3. V-bank4. Burner section5. R/A

Pagina 17 - MUA-PRC007-EN 17

24 MUA-PRC007-ENDFIAFigure 9. Twin blower models vertical unitsUnit Components1. Inlet damper2. R/A section (before burner)3. V-bank4. Burner section

Pagina 18 - 18 MUA-PRC007-EN

MUA-PRC007-EN 25DFIAFigure 10. DFIA Accessories dimensional dataTable 8. DFIA Accesories dimensional dataModel A B C D E109–112 2 ft 5 in 3 ft 9 in 1

Pagina 19 - MUA-PRC007-EN 19

26 MUA-PRC007-ENDFIAWeights Figure 11. DFIA approximate weightsRETURN AIRTable 9. DFIA Approximate weightsUnit SizeBlower SectionVertical Support Sta

Pagina 20 - CFM Std. Air

MUA-PRC007-EN 27DFOAModel Number DescriptionsDigit 1, 2, 3 — Unit TypeDFO= Direct-Fired Outdoor UnitDigit 4 — Development SequenceA = First Generation

Pagina 21 - Dimensions

28 MUA-PRC007-ENDFOADigit 28 — Painted Basic Unit and AccessoriesM = Painted Basic Unit and AccessoriesDigit 29 — UV Flame SensorN = UV Flame SensorD

Pagina 22 - Front View

MUA-PRC007-EN 29DFOAFeatures and Benefits

Pagina 23 - Side View

MUA-PRC007-EN 3IntroductionInstallation is simple since the unit, (when shipping permits), is shipped as a complete package. The burner is fully modul

Pagina 24

30 MUA-PRC007-ENDFOABasic UnitFeature: Casing with galvanized finish.Benefit: Rust problem is greatly reduced.Feature: Watertight construction.Benef

Pagina 25 - MUA-PRC007-EN 25

MUA-PRC007-EN 31DFOAPerformance DataTable 10. Direct-Fired Outdoor Air (DFOA) unit—General dataUnit Size 109 112 115 118 215 218 220 222 225 230Airflo

Pagina 26 - 26 MUA-PRC007-EN

32 MUA-PRC007-ENDFOA118 1–186500 2215 3 5 5 5 5 5 5 7-1/27000 2390 5 5 5 5 5 5 7-1/2 7-1/27500 2565 5 5 5 5 5 7-1/2 7-1/2 7-1/28000 2740 5 5 5 7-1/2

Pagina 27

MUA-PRC007-EN 33DFOA 225 2–2530000 2235 15 15 15 15 20 20 — —32000 2385 15 15 15 20 20 20 25 —34000 2535 15 20 20 20 20 25 25 3036000 2685 20 20 20 20

Pagina 28

34 MUA-PRC007-ENDFOA1186500 577 646 712 776 838 897 9547000 621 697 767 836 902 966 10277500 665 745 822 896 967 1035 11018000 710 795 877 955 1031 1

Pagina 29 - Features and Benefits

MUA-PRC007-EN 35DFOA23044000 3903 4372 4822 5255 5671 6072 645848000 4258 4769 5260 5732 6187 6624 704652000 4273 4883 5494 6104 6715 7325 880756000 4

Pagina 30 - Gas-Fired Unit

36 MUA-PRC007-ENDFOADimensionsFigure 12. Single blower sizes 109–130Unit Components1. Centrifugal supply fan2. Fan motor3. Line burner4. Control cabi

Pagina 31

MUA-PRC007-EN 37DFOAFigure 13. Twin blower sizes 215–230Unit Components1. Centrifugal supply fan2. Fan motor3. Line burner4. Control cabinet5. Hinged

Pagina 32 - 32 MUA-PRC007-EN

38 MUA-PRC007-ENDFOAFigure 14. Twin blower sizes 233 and 240.Unit Components1. Centrifugal supply fan2. Fan motor3. Line burner4. Control cabinet5. H

Pagina 33 - MUA-PRC007-EN 33

MUA-PRC007-EN 39DFOAFigure 15. Vertical models sizes 109–130Unit Components1. Centrifugal supply fan2. Fan motor3. Line burner4. Control cabinet5. Hin

Pagina 34 - 34 MUA-PRC007-EN

4 MUA-PRC007-ENTable of ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 35 - MUA-PRC007-EN 35

40 MUA-PRC007-ENDFOAFigure 16. Vertical models sizes 109–130 with mixing boxUnit Components1. Centrifugal supply fan2. Fan motor3. Line burner4. Cont

Pagina 36

MUA-PRC007-EN 41DFOAFigure 17. Vertical models sizes 215–230Unit Components1. Centrifugal supply fan2. Fan motor3. Line burner4. Control cabinet5. Hin

Pagina 37 - (bottom discharge)

42 MUA-PRC007-ENDFOAFigure 18. Vertical models sizes 215–230 with mixing boxUnit Components1. Centrifugal supply fan2. Fan motor3. Line burner4. Cont

Pagina 38 - Right Hand Side

MUA-PRC007-EN 43DFOA Figure 19. Vertical models sizes 233 and 240Unit Components1. Centrifugal supply fan2. Fan motor3. Line burner4. Control cabinet5

Pagina 39 - Left is opposite

44 MUA-PRC007-ENDFOAFigure 20. Vertical models 233 and 240 with mixing boxUnit Components1. Centrifugal supply fan2. Fan motor3. Line burner4. Contro

Pagina 40 - Side Discharge

MUA-PRC007-EN 45DFOA Figure 21. DFOA Accessories dimensional dataTable 22. DFOA Accessories dimensional dataModel A B C D E F G H J K L M109–112 3’

Pagina 41 - left is opposite

46 MUA-PRC007-ENDFOARoof curbs for 100% make-up air unitsFigure 22. Single blower roof curb dimensionsTable 23. Dimensions for single blower roof cur

Pagina 42

MUA-PRC007-EN 47DFOARoof curbs for 100% make-up air unitsFigure 23. Double blower roof curb dimensionsTable 24. Double blower roof curb dimensions for

Pagina 43

48 MUA-PRC007-ENDFOARoof curbs for units with return air opening downsteam of burnerFigure 24. Roof curb dimensions for single blower models sizes 10

Pagina 44 - Model A B C D E F I L M T U W

MUA-PRC007-EN 49DFOARoof curbs for units with return air opening downstream of burnerFigure 25. Roof curb dimensions for double blower models sizes 21

Pagina 45 - MUA-PRC007-EN 45

MUA-PRC007-EN 5UV Flame Sensor (UV Mini-Peeper) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65Optional Gas Controls . . . .

Pagina 46 - 46 MUA-PRC007-EN

50 MUA-PRC007-ENDFOARoof curbs for units with mixing boxFigure 26. Roof curb dimensions for single blower units with mixing boxTable 27. Roof curb di

Pagina 47 - MUA-PRC007-EN 47

MUA-PRC007-EN 51DFOARoof curbs for units with mixing boxesFigure 27. Roof curb dimensions for double blower units with mixing boxTable 28. Roof curb d

Pagina 48 - 48 MUA-PRC007-EN

52 MUA-PRC007-ENDFOAApproximate weights Table 29. Unit weights in pounds (approximate)Unit SizeBasic Horizontal UnitBasic Vertical UnitInlet HoodIn

Pagina 49 - MUA-PRC007-EN 49

MUA-PRC007-EN 53DFOAInlet Hood Support (By Others) • The purpose of hood support is to support the weight of the unit accessories which are attached t

Pagina 50 - 50 MUA-PRC007-EN

54 MUA-PRC007-ENGas PipingFigure 29. Gas pipingTable 31. Gas piping component identificationGP-01 High Gas Pressure Regulator VG-03 Auxiliary Gas Val

Pagina 51 - MUA-PRC007-EN 51

MUA-PRC007-EN 55Gas PipingExamples of how to read the above:• GP < 7 in. wc: Gas pressure less than 7 in. wc• 7 in. wc < GP < 10 in. wc: Gas

Pagina 52 - Approximate weights

56 MUA-PRC007-ENGas PipingTable 33. Gas piping connection size, standard gas trainMBhInlet gas pressure (inches of water column)7 8–11 12–14 15–20 21

Pagina 53 - MUA-PRC007-EN 53

MUA-PRC007-EN 57Gas PipingTable 34. Gas pipe connection size, FM gas trainMBhInlet gas pressure (inches of water column)7 8–11 12–14 15–20 21–27 1 psi

Pagina 54 - Gas Piping

58 MUA-PRC007-ENGas PipingTable 35. Gas pipe connection size, IRI gas trainMBhInlet gas pressure (inches of water column)7 8–11 12–14 15–20 21–27 1 p

Pagina 55

MUA-PRC007-EN 59Electrical Power Table 36. Motor electrical datahpSingle Phase Three Phase115 208 230 208 230 4601/3 7.2 4 3.6 1.4 1.6 0.71/2 9.8 5.4

Pagina 56

6 MUA-PRC007-ENApplication ConsiderationsThe Need for Make-Up Air Units When more air is exhausted from a building than is supplied by the mechanical

Pagina 57

60 MUA-PRC007-ENOptionsMotorized 75/25 DamperPurposeTo provide a way for recirculating return air and letting building pressure control the amount of

Pagina 58

MUA-PRC007-EN 61OptionsMixing Box—Temperature ControlPurposeTo provide a way for recirculating return air and letting mixed air temperature determine

Pagina 59 - Electrical Power

62 MUA-PRC007-ENOptions•Dampers• Modulating damper motor(s)• Manual potentiometerRemote control station not included. Purpose To provide a way for re

Pagina 60 - Motorized 75/25 Damper

MUA-PRC007-EN 63OptionsMixing Box—Building Pressure ControlPurpose To provide a way for recirculating return air and letting building pressure control

Pagina 61 - Mixing Box—Manual Control

64 MUA-PRC007-ENOptionsOption Includes: •Damper • Two position damper motor(s) with built-in end switch and spring return •LinkageExhaust InterlockTh

Pagina 62 - Options Include:

MUA-PRC007-EN 65OptionsExample: If we want the burner to be “off” if the entering air temperature is 65 degrees, the inlet on-off duct stat would be

Pagina 63 - Motorized Inlet Damper

66 MUA-PRC007-ENOptionsEnergy Efficient ODP 60 Hz/1800 Rp Three-Phase Only Optional 208V motors are available in 1 hp to 30 hp models. 230V and 460V

Pagina 64 - Exhaust Interlock

MUA-PRC007-EN 67OptionsMixing Box—Temperature Control This option provides a way for recirculating return air and allows mixed air temperature to dete

Pagina 65 - Factory Installed Options

68 MUA-PRC007-ENOptionsClogged Filter SwitchThis option includes a pressure sensing switch which senses the pressure drop across the filters. When t

Pagina 66 - Additional Options*

MUA-PRC007-EN 69OptionsRemote Control Station On-Off Night Setback ThermostatThis option will shut unit off when space temperature is above setpoint.

Pagina 67 - MUA-PRC007-EN 67

MUA-PRC007-EN 7Application Considerations• Drafts and cross-currents will increase in a negative condition, causing an uncomfortable or unhealthy work

Pagina 68 - Field Installed Accessories

70 MUA-PRC007-ENMechanical SpecificationsDFIA Unit Casing DFIA cabinets are designated for indoor use. Unit casing and accessories shall be fabricate

Pagina 69 - MUA-PRC007-EN 69

MUA-PRC007-EN 71Mechanical SpecificationsFM for ETL Listed UnitsFor installations with ETL labeled units requiring Factory Mutual (FM) insurance. The

Pagina 70 - Mechanical Specifications

72 MUA-PRC007-ENMechanical SpecificationsThe display functions of the BACview keypad display with a minimum of four lines, sixteen characters will in

Pagina 71 - MUA-PRC007-EN 71

www.trane.comFor more information, contact your local Trane office or e-mail us at [email protected] Order Number MUA-PRC007-ENDate November

Pagina 72 - Gas Train Approvals

8 MUA-PRC007-ENSelection ProcedureCalculating Total External Static Pressure to Determine Fan Motor Horsepower. To determine the fan motor horsepowe

Pagina 73

MUA-PRC007-EN 9Selection ProcedureBurner Selection ProcedureFor DFIA selections, use Tab l e 3 , p . 18, and select next size larger available burner

Comentarios a estos manuales

Sin comentarios