VAV-PRC011M-EN 15
Model Number Descriptions
DD92= UC210 DDC-Basic plus- Local
(Electric heat- Staged) Remote
(Staged EH)
DD93= UC210 Ventilation Flow
(Water heat- N.O. 2-position)
DD95= UC210 Basic
(Electric HeatModulating SCR)
DD96= UC210 Basic plus-Local
(Electric heat-Modulating SCR)
Remote (Staged EH)
DD97= UC210 Ventilation Flow
(Electric heat-Modulating SCR)
ENCL= Shaft Only in Enclosure
ENON= Shaft Out Side for Electric Units
FM00= Other Actuator and Control
FM01= Trane Supplied Actuator, Other
Ctrl
PC00= N.C. Actuator and Linkage Only
PC04= N.C. with DA Stat, 3000 Series
PC05= N.C. with RA STAT, 3000 Series
PCSS= Normally Closed Special
PN00= N.O. Actuator and Linkage Only
PN04= N.O. 3000 Series, DA STAT
PN05= N.O. 3000 Series, RA STAT
PN11= Auto Dual Min.
PN32= N.O. PNEU Constant Vol.
PN34= N.O. 3000 Series Constant
Vol.,RA STAT
PNON= Shaft Out Side for Pneumatic
Units
PNSS= Normally Open Special
N.C .= Normally-closed
N.O. = Normally-opened
DA Stat = Direct-acting pneumatic t-stat
(by others)
RA Stat = Reverse-acting pneumatic
t-stat (by others)
PN = Pneumatic
FM = Factory installation of customer-
supplied controller
PVR = Pneumatic Volume Regulator
Digit 16—Insulation
A = 1/2" Matte-faced
B = 1" Matte-faced
D = 1" Foil-faced
F = 1" Double-wall
G = 3/8" Closed-cell
Digit 17 & 18—Not Used
00 = N/A
Digit 19—Outlet Plenum
(Connection is Slip & Drive)
0= None
A = 1 Outlet RH
B = 1 Outlet END
C = 1 Outlet LH
D = 2 Outlets, 1 RH, 1 END
E = 2 Outlets, 1 LH, 1 END
F = 2 Outlets, 1 RH, 1 LH
H = 3 Outlets, 1 LH, 1 RH, 1 END
J = 4 Outlets, 1 LH, 1 RH, 2 END
Note: See unit drawings for outlet sizes/
damper information.
Digit 20—Not Used
0= N/A
Digit 21—Water Coil
0= None
1= 1-Row
2= 2-Row
3= 3-Row
4= 4-Row
A= 1-Row Premium
B = 2-Row Premium
C = 3-Row Premium
D = 4-Row Premium
Digit 22—Electrical Connections
F = Flippable (can be flipped in the
field for LH or RH connections
- VCEF only)
L = Left (Airflow hitting you in the
face)
R = Right (Airflow hitting you in the
face)
0 = Opposite side connection – coil
and control (VCWF only)
Note: VCCF, VCWF can be flipped in field
for opposite-hand connection
Digit 23—Transformer
0= None
1 = 120/24 volt (50 VA)
2 = 208/24 volt (50 VA)
3 = 240/24 volt (50 VA)
4 = 277/24 volt (50 VA)
5 = 480/24 volt (50 VA)
6 = 347/24 Volt (50 VA)
7 = 380/24 Volt (50 VA)
8 = 575/24 Volt (50 VA)
Note: For VCEF units with transformers
the VA depends on the staging,
control, and contactor type
(ranges are 50 VA to 75 VA, for 1
and 3 phase)
Digit 24—Disconnect Switch
0= None
W= With
Note: VCCF, VCWF – Toggle Disconnect;
VCEF – Door Interlocking Power
Disconnect
Digit 25—Power Fuse
0= None
W= With
Digit 26—Electric Heat Voltage
0= None
A = 208/60/1
B = 208/60/3
C = 240/60/1
D = 277/60/1
E = 480/60/1
F = 480/60/3
G = 347/60/1
H = 575/60/3
J = 380/50/3
K = 120/60/1
Digit 27 - 29—Electric Heat kW
000= None
010 = 1.0 kW
015 = 1.5 kW
460 = 46.0 kW
Note: 0.5 to 8.0 kW – ½ kW increments
8.0 to 18.0 kW – 1 kW increments
18.0 to 46.0 kW – 2 kW increments
Digit 30—Electric Heat Stages
0 = None
1 = 1 Stage
2 = 2 Stages Equal
3 = 3 Stages Equal
Digit 31—Electrical Heat
Contactors
0 = None
1 = 24-volt magnetic
2 = 24-volt mercury
3 = PE with magnetic
4= PE with mercury
5 = SCR heat UC400/UC210
6 = SCR heat FMTD/ENCL/DD00
A = 24-volt mercury (left hand)
B = 24-volt mercury (right hand)
C = PE with mercury (left hand)
D = PE with mercury (right hand)
Digit 32 & 33—Not Used
00 = N/A
Digit 34—Actuator
0= Standard
A = Spring Return (Normally Open)
B = Spring Return (Normally Closed)
C = Belimo Actuator
Digit 35—Sensor Options
0 = Standard (Wired)
1 = Factory Mounted Wireless
Receiver (Sensor Accessory)
2 = Wireless Communications
Interface
3 = Trane Air-Fi Wireless
Communications Interface
Digit 36—Pre-Wired Factory
Solutions
0 = None
1 = Factory Mounted DTS
2 = HW Valve Harness
3 = Both DTS & HW Valve Harness
4 = Averaging DTS factory installed
in unit (Required for
UC210/UC400 with SCR heat)
Digit 37—Bottom Access with Cam
Locks
0 = None
1 = Access Left Side Terminal Unit
2 = Access Right Side Terminal Unit
3 = Access Left Side Terminal Unit
with Water Connection on Right
4 = Access Right Side Terminal Unit
with Water Coil Connection on
Left